Specifications
– Nominal Power: 6000 VA / 5400 W
– Input: Single-phase
– Nominal Voltage: 220VAC / 230VAC / 240VAC
– Nominal Frequency: 50Hz/60Hz automatic selection
– Voltage Range: 120 – 276Vac
– Frequency Range: 45 – 65Hz
– Bypass Voltage range:
* 220Vac max:default +25% (+10%, +15%, +20%, +25%)
* 230Vac max:default +20% (+10%, +15%, +20%)
* 240Vac max:default +15% (+10%, +15%)

* min:default 45% (-20%, -30%, -45%)
– Bypass Frequency range: +/-1%, +/-2%, +/-4%, +/-5%, +/-10%
– THDi:
* <=3% (100% linear load, input THDV <=1%) * <=5% (100% non linear load, input THDV <=1%) - Number of batteries: 16 blocks Standard - 18/20 blocks (configured) - Type of battery: * 12V / 7Ah * Maintenance-free, sealed lead-acid - Type of recharging: Fast charging or trickle charge automatically - Recharge time: Fast up to 20h (Max) - Maximum recharge current: 1A (standard unit) - Output: Single-phase - Voltage tolerance: +/-1.0% - Voltage distortion (THD): * Less than 2% with 100% linear load * Less than 5% with100% non linear load - Nominal Voltage: 220V/230V/ 240Vac selectable - Frequency regulation: * +/-0.1% (single unit) * +/-0.25% (parallel units) - Frequency: * When Mains present: UPS takes the same * In battery mode: 50Hz / 60Hz - Frequency synchronization: * 1Hz/s (single unit) * 0.5Hz/s (parallel units) - Overload with mains presence: * 105 % - 110 %,1h max. * 110% - 125%, 10 min max. * 125% - 150%, 1 min max. * >150% switch to bypass
– Overload on bypass:
* Feed the laod for long time if output current is <125% * Overload on Bypass is limited by the switch on bypass line - Crest factor: 3:1 - AC efficiency: => 90%
– Dynamic response:
* +/-5.0% (with load 0% to 100%)
* <= 5% in one cycle - Current limit on inverter output: When istantaneous current is 2 ~ 3 times than nominal peak current (1.414 *nominal power/(3 * 220)) the inverter enter in current limitation mode - DC component: <= 200 mV - Switch Time: 0 ms - from Mains to battery, from Inverter to bypass - Noise: < 55dB (1m) - Display: LED + LCD - Insulation resistance: > 2M Ohm (500Vdc)
– Voltage insulation: 2820Vdc, <3.5mA, 1min - IP protection grade: IP 20 Environmental conditions
– Temperature 0C – 40C (battery excluded)
– Humidity 0 – 95% no condensation
– Altitude: <1500m if >1500m power is reduced

Dimensions / Weight
– Dimensions (H×W×D): 616× 250×502 mm
– Weight: 62 kg